Steel Line Girder Check

Design check of continuous composite steel plate girders and rolled beams, with performance ratios for every limit state and a load rating: AASHTO LRFD (9th or 10th edition, HL-93) with MBE LRFR, or the AASHTO Standard Specifications 17th edition Load Factor Design (HS loading) with MBE LFR. Edit any input and results update. An MDX input file can be imported to fill the inputs.

Design specification

Design check, performance ratios

Ratio = factored demand ÷ factored resistance, worst location along the girder. Tap a tile to open the checks at that point.

Load rating summary

MBE LRFR, HL-93 design load

Calculation report

PDF, letter size

The PDF carries a blank “Checked by” field for independent review. The title-block entries are saved with the input JSON. If this preview does not allow downloads, open the tool from the Bridge SE site.

Performance ratio along girder

FlexureShearFatigueService IIConstructibility

9th vs 10th edition

    Girder elevation

    Point detail

    Governing checks

    Worst location of each check

    Moment envelope, per girder

    DC1DC2 + DWHL-93 maxHL-93 minFatigue truck range

    Shear envelope, per girder

    DC + DWHL-93 maxHL-93 min

    Inventory rating factor along girder

    Flexure, Strength IShear, Strength IService II

    Values above 4.0 are drawn at the top edge.

    Results by point of interest

    Sections, distribution factors, bracing and deflection

    Section properties

    Live-load distribution factors, 4.6.2.2

    Cross-section proportion limits, 6.10.2

    Unbraced lengths, bottom flange in negative flexure

    Live-load deflection, 2.5.2.6.2

    Method and assumptions